AdrianDBW

I've just finished this and didn't blow anything up or set anything on fire, so figured I'd stick up some words and pictures as a reference if anyone else fancies doing this.

Part 1- Modify the Urn

The urn I used is a 'Vonshef' 20L urn, which was the cheapest urn I could find- it was 37quid brand new off ebay. It's got a 'concealed' element, which may be an advantage in brewing, but other than that it isn't anything special- just a cheap Chinese made thing. It's rated at 2500W (you can see it has a 1500W and 1000W element in parallel). It will boil a full 20 litres in about 40-45 minutes.

Most urns have two temperature switches- a 95 degree switch (black switch on the left of the photo below), that will turn off the full power and switch to 'keep warm' and a boil dry switch (pinkish coloured switch in the centre)- which stops it melting itself if there's no water in it.


IMG_20171109_153455016_HDR.jpg

Most of the other sources I read for doing this, they disconnect any of the urn's electronics and connect the mains power straight to the element. I figured that the on/off switch was actually useful, and so was the boil dry switch (in case I left it on when emptying out the wort!).

IMG_20171109_164814492.jpg

The way I did it, was to remove the 95 degree (black) switch from its boss (and put the screws back in incase I ever want to turn this back into an actual urn), cover the switch in heatshrink (probably not necessary, but it stops it touching anything) and...

IMG_20171109_165816145.jpg 
Cable tie it to the bottom cover to keep it away from the heat, to stop it cutting off!

I'm not saying to bypass the urn's electrics isn't the right way to do it, but I figured this was both the easiest and safest way to mod the urn, whist still giving me the option to 'fix' it if the wife one day decides to hold a tea party...

 

Part 2 to follow...

Reply 0 0
Pinto
Need a boil-o-matic m8 ? Sure I can help.  You'll need to do the urn wiring tho.
" People say I got a drinkin' problem....But I got no problem drinkin' at all"
Reply 0 0
Clibit
Pinto wrote:
Need a boil-o-matic m8 ? Sure I can help.  You'll need to do the urn wiring tho.


I don't know what I need tbh. I shall have a read over the weekend. Might have a mate who can help with wiring if necessary. I'll come back to you if I need to. Cheers Jeff.   [thumb]
Reply 1 0
Gregles
My burco is still in its original unmodded condition even the tap is as the tea urn god intended. I just tip it up after the wort has chilled and get as much in the fv as I can. I sometimes even by pass the tap🕺🤪🍔
Reply 0 0
Pinto

Clibit wrote:


I don't know what I need tbh. I shall have a read over the weekend. Might have a mate who can help with wiring if necessary. I'll come back to you if I need to. Cheers Jeff.   [thumb]

 

No worries m8 😉 let me know

" People say I got a drinkin' problem....But I got no problem drinkin' at all"
Reply 0 0
Clibit
Gregles wrote:
My burco is still in its original unmodded condition even the tap is as the tea urn god intended. I just tip it up after the wort has chilled and get as much in the fv as I can. I sometimes even by pass the tap🕺🤪🍔


My mate's is unmodded and boils really well. This one is designed to heat the water then cut out, and only come back on when the temperature drops, to maintain a temperature. So it needs that bit by passing at least. 
Reply 0 0
Pinto
There's a difference between the boilstat and the cutout m8 😉 I prefer to be fully in control hence why I like my digital SCR which is hardwired direct to the element.
" People say I got a drinkin' problem....But I got no problem drinkin' at all"
Reply 0 0
Clibit
Pinto wrote:
There's a difference between the boilstat and the cutout m8 😉 I prefer to be fully in control hence why I like my digital SCR which is hardwired direct to the element.


I only vaguely understand that. It's like a foreign language with the occasional English word lobbed in. 
Reply 1 0
Gregles
Clibit wrote:


I only vaguely understand that. It's like a foreign language with the occasional English word lobbed in. 


That’ll be like a conversation with me then😂
Reply 1 0
Clibit
Gregles wrote:


That’ll be like a conversation with me then😂


Your foreign words are entertaining. 😃

Reply 1 0
Pinto

Clibit wrote:


I only vaguely understand that. It's like a foreign language with the occasional English word lobbed in. 

 

Clicky on-off thing good, clicky switch off permanent thingy bad. [rofl]

" People say I got a drinkin' problem....But I got no problem drinkin' at all"
Reply 0 0
Clibit
Pinto wrote:

Clicky on-off thing good, clicky switch off permanent thingy bad. [rofl]



Don't really get that either! [rofl]

Is one a manual switch and the other thermostatically controlled? It's the thermostat that needs taking out of the equation isn't it?!
Reply 0 0
Pinto
For full control, both do.  If your boiler has the 110 degree setting on the dial, it can be used to boil and just the cutout is bypassed.  If the max temp is 100, the boilstat at must be bypassed as well
" People say I got a drinkin' problem....But I got no problem drinkin' at all"
Reply 0 0
AdrianDBW
I've done both of my urns in different ways- one I have just unbolted all the sensors and cable tied them out of the way so they won't see anywhere near 100 degrees. This involved no electrical changes. The other I took all the wiring out, and then used the bits of wire to connect the elements straight to the power cable. They both work well and are controlled by PCBs that I bought from ebay that Pinto suggested.

I was wondering if a plug-in motor speed controller be a more suitable option that using one of those SCR boards for someone who's a bit concerned of their own technical abilities?? 4000W ones are readily available, I'll have to see if I can find something more beefy- we've got one in work that's around that size, we use to control a cooling fan, but it's very old.
Reply 0 0
Clibit
Thanks Adrian, and Jeff, I'll have a chat with my mate and see if we can work out a plan. Moving the sensors sounds simple enough. A controller would enable me to control mash temperature? Is that it's sole purpose?
Reply 0 0
AdrianDBW
It's so you can control the boil- otherwise you'll have to cut the power to prevent boil overs, and your boils will all be frantic.

With the controller I have I usually have mine at 100% power, then just before hot break pull it back to 55% and leave it there. This gives a rigorous enough boil without any boil overs.
Reply 0 0
Reply