GHW
I went to check on my kegged bitter just now and something odd appears to have happened.

my co2 tank seems to be empty of co2, in so far as when you open the main valve, nothing comes out. However the gauge shows the tank is 2/3 full. (See photo)

my suspicion Is that the gas wasn’t connected properly (reconditioned keg with stiff posts) and it’s all leaked out. But I’d didn’t hear anything escaping when I connected it. I’d set it at 20psi, it’s now showing 0. But the Tank gauge is confusing me.

im a complete fool at this sort of thing. What’s the most likely explanation? An empty tank with dodgy gauge or an accurate gauge and for some reason I can’t get the gas out?

oddly the beer is slightly carbed though I pushed a fair bit of co2 in before putting the gas at 20psi
Reply 0 0
Alcoholx
disconnect the regulator from the bottle and open the valve on the bottle..  see if the gas comes out fast...  or at all
Reply 1 0
GHW
Alcoholx wrote:
disconnect the regulator from the bottle and open the valve on the bottle..  see if the gas comes out fast...  or at all


really? Is that sensible? POV: I am generally terrified of the thing 
Reply 0 0
Alcoholx
Itl just go whoosh...  If it's full..   more of a fart if it's empty. 😂.   Obviously remember to close it when you find out which one..  😝
Reply 1 0
Alcoholx
On a serious note..  it won't hurt you... Just blip open the valve to see if you get a whoosh of gas...  If it's a bit tame then the bottle is likely empty... But I am more inclined to believe the gauge

do you have a secondry gauge?
Reply 0 0
GHW
Alcoholx wrote:
On a serious note..  it won't hurt you... Just blip open the valve to see if you get a whoosh of gas...  If it's a bit tame then the bottle is likely empty... But I am more inclined to believe the gauge

do you have a secondry gauge?


Ok will give it a go tomorrow! Thanks 

by secondary do you just mean another gauge?
Reply 0 0
Alcoholx
Yea..  you got the regulator pictured on the bottle.. but you said you had set the keg to 20psi
..  is it a welding regulator with 2 gauges?
Reply 0 0
GHW
Alcoholx wrote:
Yea..  you got the regulator pictured on the bottle.. but you said you had set the keg to 20psi
..  is it a welding regulator with 2 gauges?


its got the one shown and the psi gauge.
Reply 0 0
bigmack
I blast the full canister when it's new to clear any dust out before I attach a reg. Makes a hell of a screech but you only need open it for a microsecond to tell if there is anything in it.
Reply 1 0
GHW
I suspect it’ll be empty, will give this a go at some point. Might need a new regulator!
Reply 0 0
bigmack
Unless you put the tape on the reg in a duff manner then I would doubt it's that which has gone wrong.

I had a slow leak recently and it was a bugger to track down. Turned out to be the gas in post which was ancient. The internal o-ring was completely buggered.

I picked up two new posts for £5 and the keg is good as new.
Reply 0 0
GHW

It’s weird as there seemed to be plenty of gas in the tank when I was kegging and purged the air out, then when I set the Psi and connected the gas to the keg it didn’t make any noise (usually you hear the whooshy whine). 

ill have to take the reg off and see what gives 

Reply 0 0
EspeciallyBitter
bigmack wrote:
I blast the full canister when it's new to clear any dust out before I attach a reg. Makes a hell of a screech but you only need open it for a microsecond to tell if there is anything in it.
In a previous life I used to work in a genetics lab on fruit flies. To handle the flies under a microscope you knock them out by trapping them on a porous pad through which CO₂ is flowing, then you brush them back into their little vial and they wake up again a few minutes later. We used a lot of CO₂ cylinders. You had to issue a warning before blowing the dust out of the connector otherwise it would make everyone in the room jump – not always a good idea when people are trying to work with something under a microscope.
Reply 1 0
Robert
CO2 cylinders have liquid CO2 in them, they remain at constant pressure until they're nearly out of gas, when there is no liquid CO2 left. The only reason they show different pressures is down to temperature, the warmer they are, the more pressure inside. The only good way to tell how much gas is left is to weigh the cylinder when it's full and keep track of how much the weight reduces as you use the gas.

Your picture above tells me there's another picture but if there is, it won't open.

If the other end of the gas line from that regulator has a closed disconnect or some other kind of device with a closed valve on it, you wouldn't expect opening the main valve to have any effect so perhaps the problem is at the other end? If the disconnect hasn't engaged on the post properly it may not have opened.
Reply 0 0
bigmack
In a previous life I used to work in a genetics lab on fruit flies. To handle the flies under a microscope you knock them out by trapping them on a porous pad through which CO₂ is flowing, then you brush them back into their little vial and they wake up again a few minutes later. We used a lot of CO₂ cylinders. You had to issue a warning before blowing the dust out of the connector otherwise it would make everyone in the room jump – not always a good idea when people are trying to work with something under a microscope.


The wife did her PhD on drosophola!
Reply 0 0
Reply