AdrianDBW
Does anyone use a recirculating chiller?


Instead of chucking gallons of tap water away, I was wondering if I could put a pond pump in a bucket, run it through a chiller in the wort and then back into a bucket- maybe running it through an automotive oil cooler* if the water in the bucket gets hot too quickly.

I'm not anticipating this to get the wort down to pitching temperatures instantly- more looking to get that initial crash cool.


*something like this;
http://www.ebay.co.uk/itm/Aeroline-10-13-15-Row-Oil-Cooler-1-2-BSP-MGB-MIDGET-MINI-FORD-TRIUMPH/152139510582


Just after some info/opinions really, before I go and waste any time and/or money!
Reply 0 0
Alcoholx
a flash cooler with a re-circ pump may do what your thinking..
Reply 0 0
Pete
mines like this 

  WP_20171116_13_58_00_Pro.jpg 

it recirculates back to the BK, then the hot water from the chiller gets collected in the HLT / MLT each tank has a run off so when it fills or the cooling water goes cold I can  run it to a drain. you could set the chiller in ice to improve the efficiency and reduce water usage.



 Pesh
Head distiller @ Stanaways Craft Distillery
 
Reply 1 0
Pinto
My old counterflow chiller was very effective and frugal - 25l batches chilled from boil to pitch with the use of 16-18l of cold tap temp water, and even my immersion chiller on my current rig only uses 25-28l.  None of this is wasted as the hot runoff is saved in a spare FV and then used in the cleaning process [smile]

Pumped recirculation systems are only really effective if you save a large thermal mass of cold water for the chilling side - I knew a guy whose heat exchanger used to run through his outside fish pond ! 🤔 
" People say I got a drinkin' problem....But I got no problem drinkin' at all"
Reply 0 0
AdrianDBW
Pinto wrote:
My old counterflow chiller was very effective and frugal - 25l batches chilled from boil to pitch with the use of 16-18l of cold tap temp water, and even my immersion chiller on my current rig only uses 25-28l.  None of this is wasted as the hot runoff is saved in a spare FV and then used in the cleaning process [smile] 


Is it just a copper coil immersion chiller, or have you got something more complicated?

Pinto wrote:
Pumped recirculation systems are only really effective if you save a large thermal mass of cold water for the chilling side - I knew a guy whose heat exchanger used to run through his outside fish pond ! 🤔 


I was actually considering getting one of those 200L rain water buts and putting a coil in the bottom of it- take the heat out of the wort and put it into the rainwater.
Reply 0 0
Pinto
My current cooler is just an immersion coil - my CFC is set up to run on my big 50l kit.  Mind you, a 200l water butt would work well. - but do consider that the heat from the wort will be wasted for the gain of a few litres of water saved. Depends on what you want [smile]
" People say I got a drinkin' problem....But I got no problem drinkin' at all"
Reply 0 0
AdrianDBW
Well I could fill a bucket up with the hot water then connect it to the water butt...
These are definitely next year projects though! 😂
Reply 0 0
Reply