PeeBee
My first post on this forum, so I better make it count. 😁
 
My water is less than 100ppm dissolved minerals. I'm outside the range of most people in the UK, but this fairly recent (economically) "RO water" caper has put a lot more people into the same camp.
 
I've struggled recently to achieve a decent mash pH … even to get above pH5.0 or 5.1, never mind reach 5.3 or 5.4. I really don't like the idea of adding 4 to 6 grams (and more) of sodium bicarb into a mash for 20-23L beer, but that's what water calculators tell me. My preference is for low carbonated, "traditional" British beer that often has quite a high suggested mineral content. I'll often use a so-called "all-in-one" brew system in "no-sparge" mode, I've got a 3V system but it's been out-of-commission for most of two-three years … I believe now this sequence of events has got a lot to do with my low mash pH woes.
 
 
My plan at the moment: It's fairly bold so I'm asking if others have already explored this territory, and am I heading down a blind alley? I want to scrap this "mash thickness" idea as of no value and stick to two or three "fixed" mash water quantities to make things easier (like BIABers will often use full-boil-volume-mashes which is the same thing). I want to scrap most mash water additions and put them in later (sparge, steep or a "second-stage" dextrin mash). Restrict the calcium (having removed magnesium) in the main mash to only what's needed by the mash (which seems to be very little). The later is the most controversial, it's a form of "normalisation".
 
The moves radically reduces the amount of calcium in the main mash, limits the pH lowering due to calcium (hardness salts) in the main mash, and massively simplifies water calculations overall.
 
"Bru'n Water" is proving to be very good for calculating these changes (including having dual mash profiles, but that's a bit of a "bodge" … it doesn't do it in a "nice" way!).
 
Will it work? 🙈
 
Hello everyone (by-the-way … I am a newbie so need to be polite).
Water report demystified (the "Defuddler"; removes the nonsense!): https://drive.google.com/drive/folders/1oxOsH7iupwt2b1ApD44ZZxPx419P-YqQ?usp=sharing
Reply 1 0
Ceejaydubya69
I know this a daft question probably but have you tried your ph meter in your tap water? I have the same one as that and I'm not sure they are fit for purpose really, it reads about the same as yours in any wort I have put it in. And it says my tap water is 5.2 which it aint. Your ph strip looks darker than 5.0 to me so inbetween 5.2 and 5.4?
Reply 0 0
Pete
 I would ditch both the probe and the pH papers there not worth bothering with
Head distiller @ Stanaways Craft Distillery
 
Reply 3 0
Ceejaydubya69
100% Pete. The ph meters are useless, don't bother anymore
Reply 2 0
PeeBee
 
Oh dear. Sounds almost like everything that could go wrong did go wrong. Sometimes though, c**k up is the mother of invention! Let's hope so. 😃
I think my partner is a little premature reallocating my Grainfather brewing gear though?
 
[202925%2F9373056%2Fmceclip0]
Water report demystified (the "Defuddler"; removes the nonsense!): https://drive.google.com/drive/folders/1oxOsH7iupwt2b1ApD44ZZxPx419P-YqQ?usp=sharing
Reply 1 0
Martin Kernick
pH measurement requires some delicate equipment. From memory, in the lab, I was constantly calibrating the pH meter. As I remember it (it was a long time ago), the probe needed to be soaked in a special solution too to prevent any bacteria growing on the semi permeable surface. The calibration solutions have a tendency to grow stuff too, meaning that they can't be relied upon beyond a few days.  
 
Having said that, if, after calibration and using fresh calibration solutions at 3 ph levels, you get consistent readings from day to day from those solutions, then I guess that your pH meter is reading accurately enough to be relied on within that range.
Reply 0 0
PeeBee
100% Pete. The ph meters are useless, don't bother anymore
That's where I want to be! I want to go through the motions of showing "pH" is only a rough indicator and certainly not something to be slaved to. It should be good fun going back to that American forum and tell them that being a slave to its "accurate" indications is a complete waste of time (there's no direct connection with "alkalinity" and that's what should be monitored).
 
But! It's "roughly indicating" to me that something isn't right. So I'm not giving up on pH (as a rough indicator) just yet. The pH pen is new (this was its first outing) and calibrated the day before, and on the day for good measure (it didn't need it).
 
Going forward: I used the same pH calibration solutions for this meter. I've got a different brand of solutions, I'll use them to cross-reference the checks (not convinced that'll find anything). And … probably for the time I've had the issue (3 or four years), I've mainly used Chavallier barley malt. From two, consecutive, uncrushed grain, 25Kg sacks (I wasn't brewing in 2024, so I'm currently using up old stock!). My next brew must be something different.
Water report demystified (the "Defuddler"; removes the nonsense!): https://drive.google.com/drive/folders/1oxOsH7iupwt2b1ApD44ZZxPx419P-YqQ?usp=sharing
Reply 0 0
Ceejaydubya69
I think you're putting too much emphasis on what a cheap ph pen is telling you tbh. I have just looked on geterbrewed website just as an example, they have a £10 one, £20 one and £36 one. There has to be a difference between them I would think.
Reply 0 0
PeeBee
I think you're putting too much emphasis on what a cheap ph pen is telling you tbh. I have just looked on geterbrewed website just as an example, they have a £10 one, £20 one and £36 one. There has to be a difference between them I would think.
All I want from the pH pen is an indication of pH ±0.1: So I know the combination I'm using is falling in the right area. I'm not wanting ±0.01 accuracy and certainly don't want to pay the price tag attached to such things (the capable ones that is). What am I going to do if my pH is off-the-mark by 0.03? The "mark" having been determined to four decimal places by someone in his single bed flat's kitchen? "To much emphasis"? I think you'll find I'm actually "sceptic³ ".
 
When I'm in the position to say we're wasting our time with pH meters, I will need to be confident in what I say. I just don't think I'm in that position … just yet! (Something to do with my mash pHs failing to register greater than 5.1).
 
But, I'm heartened by what you're saying. There's a hell of a lot of other people out there that think "pH" is the be-all-and-end-all of accurate mashing. They won't want to listen to your preaching. But I do believe it's them that have it so wrong!
Water report demystified (the "Defuddler"; removes the nonsense!): https://drive.google.com/drive/folders/1oxOsH7iupwt2b1ApD44ZZxPx419P-YqQ?usp=sharing
Reply 0 0
Ceejaydubya69
Ok
Reply 0 0
Chug
Probably be the best beer you've ever made and you won't be able to recreate it!
Reply 0 0
PeeBee
Probably be the best beer you've ever made and you won't be able to recreate it!
Thanks. I've recorded so much drivel with it, I possibly could recreate it!
 
I'm not too worried about the stout itself, it has finished fermenting at 1.021, but I was only wanting to get it down to 1.017 (the FG derived by Ron's research of Whitbread's records). The other yeasts I'd purchased in a hurry, nor the "Glucoamylase" enzyme, were needed so they'll wait until I have my next disaster. If I'd thought about it and not switched to "headless chicken" ("panic") mode, I might of figured that out and saved myself the anxiety (and pocket-money). (I've brewed 5-6% ABV historical "ale" creations mashed for an hour at 72°C … five minutes at 74°C wasn't going to be the end of the world).
 
I switched the yeast from Lallemand Windsor to a "more aggressive" Mangrove Jack's M42. S33 or WY1099 (liquid) are my usual choice for "dextrin-averse" yeast, but "dextrin-averse" isn't what I needed in this case! I did lose quite a lot of expected extract, but that was more likely me being a cheapskate and trying to get away with out-of-date malt.
 
 
The big loss, is I didn't get to figure out why I get such low mash pHs. Guess it'll be a "try, try and try again" job.
Water report demystified (the "Defuddler"; removes the nonsense!): https://drive.google.com/drive/folders/1oxOsH7iupwt2b1ApD44ZZxPx419P-YqQ?usp=sharing
Reply 0 0
PeeBee
I've found the probable cause for the issue I've been experiencing, and I guess I've been a bit mean: I've not fully outlined the procedures I use, so no-one here had any chance of figuring out the reasons. Oops … Sorry!
 
I perform "mashin" with Grainfathers using the traditional "strike" temperature rather than letting the Grainfather bring the heat back up to mashing temperature after "mashin" (because I don't believe it, or any of these "AIOs", can go that very well). Somehow something had changed (i.e. I changed something but I know not what) resulting in Grainfather recording too small an amount of mash water and therefore exaggerates the "strike temperature". I've "full-boil-length-mashed" for so long, I was suspicious of the high strike temperature in this case, but not suspicious enough to question it. Add to that how I was calculating water salts and seems I may have been mucking that up too.
 
What I'd thought was a clever work-around turned out to be creating a noose for my own neck. I'll have it fixed shortly …
Water report demystified (the "Defuddler"; removes the nonsense!): https://drive.google.com/drive/folders/1oxOsH7iupwt2b1ApD44ZZxPx419P-YqQ?usp=sharing
Reply 1 0
Martin Kernick
I've found the probable cause for the issue I've been experiencing, and I guess I've been a bit mean: I've not fully outlined the procedures I use, so no-one here had any chance of figuring out the reasons. Oops … Sorry!
 
I perform "mashin" with Grainfathers using the traditional "strike" temperature rather than letting the Grainfather bring the heat back up to mashing temperature after "mashin" (because I don't believe it, or any of these "AIOs", can go that very well). Somehow something had changed (i.e. I changed something but I know not what) resulting in Grainfather recording too small an amount of mash water and therefore exaggerates the "strike temperature". I've "full-boil-length-mashed" for so long, I was suspicious of the high strike temperature in this case, but not suspicious enough to question it. Add to that how I was calculating water salts and seems I may have been mucking that up too.
 
What I'd thought was a clever work-around turned out to be creating a noose for my own neck. I'll have it fixed shortly …
All's well that ends well. 🙂 That's the thing with brewing. So many variables, so many calculations etc... but most of us wouldn't enjoy it as much if it wasn't a bit complex.
Reply 1 0
PeeBee
I did uncover the errors I was making in my "normalization" fix above … I was "normalizing" the calcium additions additions to the mash, but neglecting the water itself, which was increasing by 50% along with all the calcium that contained (21.9ppm calcium … flippin' "concentration values", I'm trying to fix the distortions they create and one sneaks in behind me and undoes it!).
 
The "strike temperature" error was down to a misunderstanding what "recoverable dead space" can mean. It's been purged too. (I was aware of the potential problems with my ancient Grainfather strike temperature fix … but I'd forgotten all that; like you do? Well, like I do for sure).
 
 
I'll not bore the readers here with my next brew (a "Bitter", so there won't be a lot of "normalization" needed to be going on, and I've got enough "Stout" to drink for now!). I'll be back to this thread in a month or so.
Water report demystified (the "Defuddler"; removes the nonsense!): https://drive.google.com/drive/folders/1oxOsH7iupwt2b1ApD44ZZxPx419P-YqQ?usp=sharing
Reply 1 0
Reply